POD for real-time simulation of hyperelastic soft biological tissue using the point collocation method of finite spheres. (English) Zbl 1296.74063

Summary: The point collocation method of finite spheres (PCMFS) is used to model the hyperelastic response of soft biological tissue in real time within the framework of virtual surgery simulation. The proper orthogonal decomposition (POD) model order reduction (MOR) technique was used to achieve reduced-order model of the problem, minimizing computational cost. The PCMFS is a physics-based meshfree numerical technique for real-time simulation of surgical procedures where the approximation functions are applied directly on the strong form of the boundary value problem without the need for integration, increasing computational efficiency. Since computational speed has a significant role in simulation of surgical procedures, the proposed technique was able to model realistic nonlinear behavior of organs in real time. Numerical results are shown to demonstrate the effectiveness of the new methodology through a comparison between full and reduced analyses for several nonlinear problems. It is shown that the proposed technique was able to achieve good agreement with the full model; moreover, the computational and data storage costs were significantly reduced.

MSC:

74L15 Biomechanical solid mechanics
74S25 Spectral and related methods applied to problems in solid mechanics
92C50 Medical applications (general)
92-08 Computational methods for problems pertaining to biology
PDFBibTeX XMLCite
Full Text: DOI

References:

[1] M. J. Wagner and H. A. Thomas Jr., “Application of the medical knowledge general competency to emergency medicine,” Academic Emergency Medicine, vol. 9, no. 11, pp. 1236-1241, 2002. · doi:10.1197/aemj.9.11.1236
[2] Y. Lim, Physics based digital surgery using the point associated finite field approach [Ph.D. thesis], Rensselaer Polytechnic Institute, Troy, NY, USA, 2005.
[3] E. Raposio, M. Fato, A. Schenone, et al., “An “augmented-reality” aid for plastic and reconstructive surgeons,” in Proceedings of the Medicine Meets Virtual Reality (MMVR ’5), pp. 232-235, Amsterdam, The Netherlands, 1997.
[4] T. Krummel, “Surgical simulation and virtual reality: the coming revolution,” Annals of Surgery, vol. 228, no. 5, pp. 635-637, 1998.
[5] A. Levin, “Fewer crashes caused by pilots,” Tech. Rep., USA Today, Washington, DC, USA, 2004.
[6] S. F. Frisken-Gibson, “Using linked volumes to model object collisions, deformation, cutting, carving, and joining,” IEEE Transactions on Visualization and Computer Graphics, vol. 5, no. 4, pp. 333-348, 1999. · Zbl 05108509 · doi:10.1109/2945.817350
[7] D. Terzopoulost, J. Platt, A. Barr, and K. Fleischert, “Elastically deformable models,” in Proceedings of the 14th Annual Conference on Computer Graphics and Interactive Techniques (SIGGRAPH ’87), vol. 21, no. 4, pp. 205-214, July 1987. · doi:10.1145/37401.37427
[8] S. A. Cover, N. F. Ezquerra, R. Rowe, T. Gadacz, and J. F. O’Brien, “Interactively deformable models for surgery simulation,” IEEE Computer Graphics and Applications, vol. 13, no. 6, pp. 68-75, 1993. · Zbl 05086864 · doi:10.1109/38.252559
[9] U. G. Kühnapfel, C. Kuhn, M. Hübner, H. G. Krumm, H. Maass, and B. Neisius, “The Karlsruhe endoscopic surgery trainer as an example for virtual reality in medical education,” Minimally Invasive Therapy and Allied Technologies, vol. 6, no. 2, pp. 122-125, 1997.
[10] Y. Lee, D. Terzopoulos, and K. Waters, “Realistic modeling for facial animation,” in Proceedings of the 22nd Annual ACM Conference on Computer Graphics and Interactive Techniques (SIGGRAPH ’95), pp. 55-62, August 1995.
[11] R. M. Koch, M. H. Gross, F. R. Carls, D. F. von Buren, G. Fankhauser, and Y. I. H. Parish, “Simulating facial surgery using finite element models,” in Proceedings of the 23rd Annual Conference on Computer Graphics and Interactive Techniques (SIGGRAPH ’96), pp. 421-428, August 1996. · doi:10.1145/237170.237281
[12] R. M. Kenedi, T. Gibson, J. H. Evans, and J. C. Barbenel, “Tissue mechanics,” Physics in Medicine and Biology, vol. 20, no. 5, pp. 163-169, 1975. · doi:10.1088/0031-9155/20/5/00
[13] K. Waters, “Physical model of facial tissue and muscle articulation derived from computer tomography data,” in Visualization in Biomedical Computing ’92, vol. 1808 of Proceedings of SPIE, pp. 574-583, October 1992. · doi:10.1117/12.131110
[14] S. Cotin, J. Pignon, H. Delinguette, and G. Subsol, “A craniofacial surgery simulation test-bed,” in Visualization for Biomedical Computing (VBC ’94), Rochester, Minn, USA, October 1994.
[15] S. Platt and N. Badler, “Animating facial expressions,” in Proceedings of the 8th Annual Conference on Computer Graphics and Interactive Techniques (SIGGRAPH ’81), vol. 15, pp. 245-252, August 1981.
[16] A. Gelder, “Approximate simulation of elastic membranes by triangulated spring meshes,” Journal of Graphic Tools, vol. 3, no. 2, pp. 21-42, 1998. · Zbl 05466642 · doi:10.1080/10867651.1998.10487490
[17] M. Bro-Nielsen, “Finite element modeling in surgery simulation,” Proceedings of the IEEE, vol. 86, no. 3, pp. 490-503, 1998. · doi:10.1109/5.662874
[18] S. Cotin, H. Delingette, and N. Ayache, “Real-time elastic deformations of soft tissues for surgery simulation,” IEEE Transactions on Visualization and Computer Graphics, vol. 5, no. 1, pp. 62-73, 1999. · Zbl 05108165 · doi:10.1109/2945.764872
[19] H. Delingette, N. Ayache, and S. Cotin, “A hybrid elastic model for real-time cutting, deformations, and force feedback for surgery training and simulation,” The Visual Computer, vol. 16, no. 8, pp. 437-452, 2000. · Zbl 0985.68719 · doi:10.1007/PL00007215
[20] D. James and A. Pai, “Artdefo: accurate real time deformable objects,” in Proceedings of the 26th ACM Annual Conference on Computer Graphics and Interactive Techniques (SIGGRAPH ’99), pp. 65-72, August 1999. · doi:10.1145/311535.311542
[21] K. Miller, “Constitutive model of brain tissue suitable for finite element analysis of surgical procedures,” Journal of Biomechanics, vol. 32, no. 5, pp. 531-537, 1999. · doi:10.1016/S0021-9290(99)00010-X
[22] K. Miller and K. Chinzei, “Constitutive modelling of brain tissue: experiment and theory,” Journal of Biomechanics, vol. 30, no. 11-12, pp. 1115-1121, 1997. · doi:10.1016/S0021-9290(97)00092-4
[23] K. Miller and K. Chinzei, “Mechanical properties of brain tissue in tension,” Journal of Biomechanics, vol. 35, no. 4, pp. 483-490, 2002. · doi:10.1016/S0021-9290(01)00234-2
[24] K. Miller, K. Chinzei, G. Orssengo, and P. Bednarz, “Mechanical properties of brain tissue in-vivo: experiment and computer simulation,” Journal of Biomechanics, vol. 33, no. 11, pp. 1369-1376, 2000. · doi:10.1016/S0021-9290(00)00120-2
[25] M. Farshad, M. Barbezat, P. Flueler, F. Schmidlin, P. Graber, and P. Niederer, “Material characterization of the pig kidney in relation with the biomechanical analysis of renal trauma,” Journal of Biomechanics, vol. 32, no. 4, pp. 417-425, 1999. · doi:10.1016/S0021-9290(98)00180-8
[26] N. Ayache and H. Delingette, “Soft tissue modeling for surgery simulation,” in Computational Models for the Human Body, pp. 453-550, Elsevier, 2004.
[27] S. Blemker, V. Hing, R. Fedkiw, and J. Teran, “Finite volume methods for the simulation of skeletal muscle,” in Proceedings of the Eurographics/SIGGRAPH Symposium on Computer Animation (SCA ’03), pp. 68-74, San Diego, Calif, USA, 2003.
[28] K. Miller, G. Joldes, D. Lance, and A. Wittek, “Total Lagrangian explicit dynamics finite element algorithm for computing soft tissue deformation,” Communications in Numerical Methods in Engineering, vol. 23, no. 2, pp. 121-134, 2007. · Zbl 1154.74045 · doi:10.1002/cnm.887
[29] Z. A. Taylor, O. Comas, M. Cheng et al., “On modelling of anisotropic viscoelasticity for soft tissue simulation: numerical solution and GPU execution,” Medical Image Analysis, vol. 13, no. 2, pp. 234-244, 2009. · doi:10.1016/j.media.2008.10.001
[30] S. M. BaniHani and S. De, “A comparison of some model order reduction methods for fast simulation of soft tissue response using the point collocation-based method of finite spheres,” Engineering with Computers, vol. 25, no. 1, pp. 37-47, 2009. · Zbl 05535672 · doi:10.1007/s00366-008-0103-4
[31] Y. C. Yoon, S. H. Lee, and T. Belytschko, “Enriched meshfree collocation method with diffuse derivatives for elastic fracture,” Computers & Mathematics with Applications, vol. 51, no. 8, pp. 1349-1366, 2006. · Zbl 1141.74046 · doi:10.1016/j.camwa.2006.04.010
[32] S. H. Lee and Y. C. Yoon, “Meshfree point collocation method for elasticity and crack problems,” International Journal for Numerical Methods in Engineering, vol. 61, no. 1, pp. 22-48, 2004. · Zbl 1079.74667 · doi:10.1002/nme.1053
[33] M. A. Puso, J. S. Chen, E. Zywicz, and W. Elmer, “Meshfree and finite element nodal integration methods,” International Journal for Numerical Methods in Engineering, vol. 74, no. 3, pp. 416-446, 2008. · Zbl 1159.74456 · doi:10.1002/nme.2181
[34] S. De, Y. J. Lim, M. Manivannan, and M. A. Srinivasan, “Physically realistic virtual surgery using the point-associated finite field (PAFF) approach,” Presence, vol. 15, no. 3, pp. 294-308, 2006.
[35] K. J. Bathe, Finite Element Procedures, Prentice-Hall, Englewood Cliffs, NJ, USA, 1996. · Zbl 0994.74001
[36] O. Zienkiewicz and R. Taylor, The Finite Element Method Set, Butterworth-Heinemann, London, UK, 6th edition, 2005. · Zbl 1084.74001
[37] Z. Gao, K. Lister, and J. P. Desai, “Constitutive modeling of liver tissue: experiment and theory,” Annals of Biomedical Engineering, vol. 38, no. 2, pp. 505-516, 2010. · doi:10.1007/s10439-009-9812-0
[38] R. Ogden, Non-Linear Elastic Deformations, Halsted Press, New York, NY, USA, 1984. · Zbl 0541.73044
[39] R. Ogden, “Large deformation isotropic elasticity-on the correlation of theory and experiment for incompressible rubberlike solids,” Proceedings of the Royal Society of London A, vol. 326, no. 1567, pp. 565-584, 1972. · Zbl 0257.73034 · doi:10.1098/rspa.1972.0026
[40] A. C. Antoulas, Approximation of Large-Scale Dynamical Systems, Society for Industrial and Applied Mathematic (SIAM), Philadelphia, Pa, USA, 2005. · Zbl 1112.93002 · doi:10.1137/1.9780898718713
[41] R. W. Freund, “Krylov-subspace methods for reduced-order modeling in circuit simulation,” Journal of Computational and Applied Mathematics, vol. 123, no. 1-2, pp. 395-421, 2000. · Zbl 0964.65082 · doi:10.1016/S0377-0427(00)00396-4
[42] E. Rudnyi and J. Korvink, “Review: automatic model reduction for transient simulation of MEMS-based devices,” Sensors Update, vol. 11, no. 1, pp. 3-33, 2002. · doi:10.1002/seup.200211105
[43] M. Rewienski, A trajectory piecewise-linear approach to model order reduction of nonlinear dynamical systems [Ph.D. thesis], MIT, Cambridge, Mass, USA, 2003.
[44] E. Grimme, Krylov projection methods for model reduction [Ph.D. thesis], University of Illinois at Urbana-Champaign, Champaign, Ill, USA, 1997.
[45] K. Glover, “All optimal Hankel-norm approximations of linear multivariable systems and their L\infty -error bounds,” International Journal of Control, vol. 39, no. 6, pp. 1115-1193, 1984. · Zbl 0543.93036 · doi:10.1080/00207178408933239
[46] Y. C. Liang, H. P. Lee, S. P. Lim, W. Z. Lin, K. H. Lee, and C. G. Wu, “Proper orthogonal decomposition and its applications. I. Theory,” Journal of Sound and Vibration, vol. 252, no. 3, pp. 527-544, 2002. · Zbl 1237.65040 · doi:10.1006/jsvi.2001.4041
[47] J. Lumley, G. Berkooz, and P. Holmes, “The proper orthogonal decomposition in the analysis of turbulent flows,” Annual Review of Fluid Mechanics, vol. 25, pp. 539-575, 1993. · Zbl 0782.76048
[48] T. Kim, “Frequency-domain Karhunen-Lóeve method and its application to linear dynamic systems,” American Institute of Aeronautics and Astronautics Journal, vol. 36, no. 11, pp. 2117-2123, 1998.
[49] P. Holmes, J. L. Lumley, and G. Berkooz, Turbulence, Coherent Structures, Dynamical Systems and Symmetry, Cambridge University Press, New York, NY, USA, 1996. · Zbl 0890.76001 · doi:10.1017/CBO9780511622700
[50] J. L. Lumley, Stochastic Tools in Turbulence, Academic Press, New York, NY, USA, 1971. · Zbl 1230.76004
This reference list is based on information provided by the publisher or from digital mathematics libraries. Its items are heuristically matched to zbMATH identifiers and may contain data conversion errors. In some cases that data have been complemented/enhanced by data from zbMATH Open. This attempts to reflect the references listed in the original paper as accurately as possible without claiming completeness or a perfect matching.